# HVAC maintenance checklist software for planned maintenance visits

> HVAC maintenance checklist software puts each planned visit's checklist on the technician's phone and keeps readings, photos and unit history on one record.

*Markdown mirror of https://hvacsoftware.com/preventive-maintenance/maintenance-checklist-software/.*

HVAC maintenance checklist software for planned maintenance visits automatically schedules recurring PM visits from calendar schedules and service agreements, puts the digital checklist on the technician’s phone, and keeps each unit’s history on one record.

The checklist replaces paper inspection forms, so every visit records the same steps, whoever runs it.

The software comes in two forms. CMMS (computerized maintenance management system) platforms serve facility teams that maintain their own buildings. Field service platforms serve the contractors who maintain equipment for clients. HVAC Software is built for facilities and engineering leaders at data centers, hospitals, plants, campuses and property portfolios, and for the service contractors who maintain that equipment, with in-house and contract PM visits on the same record.

## What the software should do on every planned maintenance visit

- **Recurring visits from agreements and calendars:** Visits generate on the interval each [service agreement](https://hvacsoftware.com/preventive-maintenance/service-agreements/) or calendar schedule sets, such as a spring cooling and fall heating tune-up, so no PM depends on someone remembering it.
- **Required checklists:** A planned maintenance visit isn’t done until its required steps, readings, photos or signature are entered.
- **Equipment records:** Each unit carries its site, make, model, serial number, refrigerant type, filter size, warranty and past repairs, so the technician arrives knowing what was done last time.
- **Capture on site:** Technicians record readings, photos and sign-off from a phone in mechanical rooms and on roofs, not on a clipboard they transcribe later.
- **Findings to quote:** A deficiency found on the visit becomes a repair quote on the same record, so nobody retypes it from a technician’s note.

## What a planned maintenance checklist should include

A planned maintenance checklist is split by season, with each line naming a component and the action taken on it. Readings go into fields on the job record, not free text, so they can be compared visit to visit.

### Cooling season checks (spring)

- **Filters:** Inspect and replace to the filter size on the unit record.
- **Evaporator and condenser coils:** Inspect and clean.
- **Blower and belts:** Check belt tension and wear, and inspect the blower.
- **Electrical:** Tighten connections, test contactors and capacitors, and measure voltage and amperage.
- **Refrigerant:** Measure pressures against the manufacturer’s specs and leak check.
- **Condensate drain:** Flush the line and clear the pan.
- **Thermostat and controls:** Verify setpoints and confirm the unit responds.

### Heating season checks (fall)

- **Burner:** Inspect and clean.
- **Heat exchanger:** Inspect for cracks and corrosion.
- **Ignition:** Test the ignition sequence.
- **Gas pressure and combustion:** Measure gas pressure and test combustion.
- **Flue:** Inspect venting and draft.

### Checklist lines by equipment type

- **RTU:** Run the cooling list each spring and the heating section each fall, with the unit’s roof location on its record.
- **Split system and heat pump:** Run refrigerant and electrical checks in both seasons, because a heat pump carries load year-round.
- **Furnace and boiler:** Run the heating list, with combustion readings attached to that unit’s record.
- **AHU:** Check filters, coils, blower, belts and condensate on every visit.
- **Chiller:** Log pressures and electrical readings to the chiller’s own record each visit, so trends show across visits.

## Keeping refrigerant records with the unit

EPA Section 608 governs refrigerant handling in the United States. Record every refrigerant reading, leak check and amount added on the visit where the work happened, and link it to the unit’s record. When an auditor or client asks about a unit, the history is on that unit, not spread across paper forms in a truck.

## How a service agreement becomes scheduled visits

An agreement should hold the PM program for its whole term so nobody re-enters it each season. The agreement names the units, the visit interval and what’s covered. When the agreement is sold, its visits are generated for the term.

The customer gets a reminder and a text before each visit, the technician completes the checklist on site, and the findings and photos stay with the unit. Before the agreement expires, a renewal reminder comes up so the program doesn’t lapse quietly.

## Which kind of system fits your PM visits

Compare approaches, not brand names. The question is whether the system models your sites and equipment and keeps a finding attached to the visit that found it.

| What the PM visit needs | Paper or spreadsheet checklist | Facility CMMS | PM system built for service work |
| --- | --- | --- | --- |
| Sites, units and equipment on one model | Manual | Yes, for owned buildings | Yes, per client site and unit |
| Visits generated from service agreements | No | Calendar schedules | Agreements and calendar schedules |
| Checklist required before the visit is done | No | Varies by product | Yes |
| Findings routed as covered or billable | No | Not the focus | Yes, on the same record |
| In-house and contractor visits on one history | No | In-house first | Both |
| Invoice from the finished visit | No | Not the focus | Yes |
| Agreement renewal reminders | No | Not the focus | Yes |

### Covered or billable: routing what the checklist finds

A checklist finding on a contract account has to answer one question before anyone writes a quote: does the agreement cover the work? Labor, filters and consumables named in the agreement stay covered. A failed capacitor, a cracked heat exchanger or a refrigerant leak outside its terms becomes a billable repair.

Commercial accounts add a second question: who approves the repair? A property manager may approve work on shared equipment, while a tenant approves work on equipment it pays for. Settle the approval path per site and per unit before the visit, not by phone afterward.

The finding, the quote, the approval and the invoice should stay on one record. Across a multi-site account with dozens of units, that record is how you show a client why one line was covered and another was billed.

## How HVAC Software handles planned maintenance visits

HVAC Software keeps each planned maintenance visit on one record, from the first call to the paid invoice: the visit, its checklist, readings, photos, parts and history.

- **Scheduling:** Preventive maintenance visits are generated from the calendar schedule or service agreement.
- **On the technician’s phone:** The technician’s assigned jobs and schedule show on their phone, with the visit’s checklist, notes and photos.
- **Placing the visit:** Dragging a job onto the board checks skills, drive time and conflicts, and the dispatcher confirms. AI can propose a technician and a time window, and a person decides the day.
- **The customer knows:** The customer gets a reminder before the visit and a text when it’s assigned, moved or the tech is on the way.
- **Close-out to invoice:** The invoice starts from the finished visit, on the same record.
- **One system:** Residential and commercial work run in one system, so a contractor’s agreement accounts and service calls share one history.

See a planned maintenance visit run on one record. [Book a demo](https://calendly.com/jeel-fieldcamp/30min?utm_source=hvacsoftware.com&utm_medium=cta&utm_content=preventive-maintenance-checklist)

The visit, its checklist and the unit’s history stay on one record in [preventive maintenance](https://hvacsoftware.com/preventive-maintenance/).

## Questions

### How do I prepare a preventive maintenance checklist?

Build the equipment list first, using the unit fields under “Equipment records” above, because the checklist lines depend on the equipment type. Then assign lines per type: a heat pump gets refrigerant and electrical checks in both seasons, while an AHU gets filters, coils, blower, belts and condensate on every visit. Any reading you’ll want to trend, such as chiller pressures, belongs in a field.

### What is a preventive maintenance checklist?

It’s the list of entries a planned visit owes before it counts as done. A useful test: if a second technician ran the same checklist on the next visit, could their readings be compared line for line with the first? If a line fails that test, turn it into a field with a component and an action.

### What HVAC maintenance should I do each season?

Run the cooling list in spring and the heating list in fall (both are above). The exceptions follow the equipment: heat pumps need refrigerant and electrical checks in both seasons because they carry load year-round, AHUs need the same checks every visit, and any refrigerant added should be logged to the unit for EPA Section 608 records.

### What’s the main difference between a CMMS and field service software?

The deciding question is whether you bill someone for the work. If you maintain your own buildings on calendar schedules, a CMMS fits. If you maintain client equipment under service agreements, you need covered-versus-billable routing, approvals and invoicing from the visit, which a facility CMMS doesn’t focus on.

## Related guides

- [Recurring visits](https://hvacsoftware.com/preventive-maintenance/recurring-visits/)

---

Also here: [Preventive maintenance](https://hvacsoftware.com/preventive-maintenance/) · [llms.txt](https://hvacsoftware.com/llms.txt)