# Food and beverage maintenance software for refrigeration and plant air

> Work orders, recurring maintenance and readings for the refrigeration, cold rooms and plant air in your food plant, on one record. Book an intro meeting.

*Markdown mirror of https://hvacsoftware.com/manufacturing/food-and-beverage/ — Industries / Manufacturing / Food and beverage.*

The auditor's question lands on Tuesday. HVACSoftware.com is food and beverage maintenance software, a CMMS for food and beverage plants, with [recurring maintenance](https://hvacsoftware.com/preventive-maintenance/) and one record for the refrigeration, cold rooms and hygienic air behind every line. Part of [manufacturing](https://hvacsoftware.com/manufacturing/).

[Book an intro meeting](https://calendly.com/jeel-fieldcamp/30min?utm_source=hvacsoftware.com&utm_medium=markdown&utm_content=manufacturing-food-and-beverage): 30 minutes. Bring your refrigeration and air equipment list.

## When the auditor asks for the record

- The refrigeration PM is a binder in the engine room and a spreadsheet in the office, and the two disagree.
- A rising pressure is logged at handover, and nobody owns it until a cold room swings.
- The auditor asks for last quarter's compressor record on Tuesday, and the answer is a hunt.

*Saturday, 8:30 p.m.: the filling hall calls. Compressor RC-02 has tripped in the engine room and cold room 3 is climbing.*

## The record for each system, and the clause that names it

Food manufacturing maintenance software keeps a schedule, a repair and a release for every system.

Taken from [SQF Edition 9](https://www.sqfi.com/the-sqf-code/choose-your-code/library-of-codes/edition-9/food-safety-code--food-manufacturing--edition-9), [BRCGS Issue 9](https://www.brcgs.com/documents-resources/food-safety-issue-9-standard/) and [21 CFR 117](https://www.ecfr.gov/current/title-21/chapter-I/subchapter-B/part-117) (FSMA). Your food safety plan sets the [intervals](https://hvacsoftware.com/preventive-maintenance/), and your auditor decides what satisfies a clause.

| System | What the job holds | What the standards ask for |
| --- | --- | --- |
| Ammonia refrigeration | Readings, parts and files | SQF Edition 9, 11.2.1.1 to 11.2.1.3: maintenance planned, recorded and reviewed after failures. BRCGS Issue 9, 4.7.1: a planned maintenance schedule. |
| Cold rooms and freezers | The repair job and the release | SQF Edition 9, 11.6.2.1 to 11.6.2.4: confirmed performance, temperature records, controlled defrost lines. BRCGS Issue 9, 4.15.3: storage that holds temperature. |
| Glycol loops | Supply and return readings | SQF Edition 9, 11.2.1.1 to 11.2.1.3 and BRCGS Issue 9, 4.7.1: the same recorded schedule. |
| Hygienic-zone air handlers | Filter, coil and pan readings | SQF Edition 9, 11.1.6.1 and 11.1.6.2: adequate ventilation, kept clean. BRCGS Issue 9, 4.4.10: no condensation. 21 CFR 117.20(b)(4): condensate must not contaminate food. |
| Compressed air that touches food | The filter change and a photo | SQF Edition 9, 11.5.5.1 and 11.5.5.2: clean air, maintained and monitored. BRCGS Issue 9, 4.5.3: filtered at point of use. |

## After the repair, the area is released

Cold room 3 does not go back to product until someone has looked at it. A [rule on the job's status](https://hvacsoftware.com/work-orders/workflows/) can email QA to inspect it.

- **Sat 11:20 p.m.** — The repair is closed. The technician closes job 6107 with the readings as left.
- **Sun 6:00 a.m.** — QA inspects the room. Tools and debris removed, area cleaned.
- **Sun 6:10 a.m.** — The area is released. The clearance shows who cleared cold room 3 and when.

BRCGS Issue 9, 4.7.4, and SQF Edition 9, 11.2.2.3, ask for this. The clearance is a record: it does not stop a line from starting.

## What AI does with the cold room call, and what a person decides

AI takes the routine part of the call. A person decides.

- **Voice agents** — Answer the maintenance line, take the room, the unit and a callback number, and [open the job](https://hvacsoftware.com/voice-agents/book-jobs-on-the-call/). A person: The agent transfers a live call to a person by the rules you set, or takes the details for a call back. This one is a callback.
- **AI dispatcher** — Proposes who, when and which job after a compressor trips. A person: A person applies it, and nothing is assigned until then.
- **Workflow automation** — A [rule](https://hvacsoftware.com/work-orders/workflows/) runs when job 6107 is Completed: email QA, book the seal recheck and tell the maintenance manager. A person: You write the rule, and the release stays with QA.
- **AI scheduling** — Proposes who is free for the RC-02 seal recheck, with how loaded their day is. A person: A person confirms the slot; a skill check when the job is created shows who fits.
- **Chat assistant** — Answers from the records, such as which releases are still waiting on QA. A person: A person reads the answer before it goes anywhere.

## Which record will the auditor ask for?

Tick the areas in your plant, pick the audit, and read the clause beside the record.

Clauses are read by edition from [SQF Edition 9](https://www.sqfi.com/the-sqf-code/choose-your-code/library-of-codes/edition-9/food-safety-code--food-manufacturing--edition-9), [BRCGS Issue 9](https://www.brcgs.com/documents-resources/food-safety-issue-9-standard/), [21 CFR 117](https://www.ecfr.gov/current/title-21/chapter-I/subchapter-B/part-117) and [OSHA's process safety rule](https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.119). Each area is set up as [recurring work](https://hvacsoftware.com/preventive-maintenance/).

| Area | What the standard asks for | What the job holds | Stays outside the job |
| --- | --- | --- | --- |
| Ammonia refrigeration | SQF Edition 9, 11.2.1.1 to 11.2.1.3; BRCGS Issue 9, 4.7.1 and 4.7.3; 21 CFR 117.40(a)(1); process safety, 29 CFR 1910.119(j)(4)(iv). | A job per unit with readings, parts and files. | Your process safety program and your engineering standard. |
| Cold room or freezer | SQF Edition 9, 11.6.2.1 to 11.6.2.4; BRCGS Issue 9, 4.15.3; 21 CFR 117.40(e) and (f). | The repair job, its readings and the release. | Your temperature monitoring log. |
| Glycol loop | SQF Edition 9, 11.2.1.1 to 11.2.1.3; BRCGS Issue 9, 4.7.1; 21 CFR 117.40(a)(1). | A recurring job with supply and return readings. | Your supplier's treatment reports. |
| Hygienic-zone air handler | SQF Edition 9, 11.1.6.1 and 11.1.6.2; BRCGS Issue 9, 4.4.10; 21 CFR 117.20(b)(4) and (b)(6). | A recurring job with filter, coil and pressure readings. | Your cleaning and sanitation records. |
| Compressed air that touches food | SQF Edition 9, 11.5.5.1 and 11.5.5.2; BRCGS Issue 9, 4.5.3; 21 CFR 117.40(g). | A recurring job for the filter, with a photo. | Your air quality test results. |

Your auditor and your plant's own procedure decide what counts as met.

Bring your equipment list. [Book an intro meeting](https://calendly.com/jeel-fieldcamp/30min?utm_source=hvacsoftware.com&utm_medium=markdown&utm_content=manufacturing-food-and-beverage)

## Your technicians work it from a phone, in the engine room

1. Open the [job](https://hvacsoftware.com/work-orders/) and read the unit, RC-02, and the room it serves.
2. Enter the oil pressure and the room temperature as found.
3. Photograph the seal, enter the readings as left and close the job.

## The first 30 minutes cover one room: bring its equipment list

- **First** — List the units. Compressors, condenser and receiver, and the cold rooms they serve, each with its state.
- **Then** — Set the dates. Each unit's PM dates become [recurring visits](https://hvacsoftware.com/preventive-maintenance/recurring-visits/) on the calendar.
- **Then** — Open the first job. A technician enters the first readings from a phone.

## Other places the equipment cannot stop

- **Manufacturing** — The chillers, compressed air and plant HVAC behind every production line.
- **Pharmaceutical** — Cleanroom air, clean utilities and the record quality asks about.
- **Hospitals** — Rooms that must hold pressure, and the rounds that keep them there.
- **Data centers** — Halls, change windows and redundancy on one work order.

## Questions food plants ask

### What do SQF auditors look for?

[SQF Edition 9](https://www.sqfi.com/the-sqf-code/choose-your-code/library-of-codes/edition-9/food-safety-code--food-manufacturing--edition-9) asks for planned maintenance recorded on a control schedule (11.2.1.1 to 11.2.1.3). It also asks for failures to be documented and reviewed, and for an inspection before operations restart (11.2.2.3). The job holds each per unit, and your auditor decides what satisfies the clause.

### What is the role of HVAC systems in the food industry?

Air handlers control ventilation, condensation and dust where food is open. The standards ask for them to be maintained and kept clean: see [SQF Edition 9](https://www.sqfi.com/the-sqf-code/choose-your-code/library-of-codes/edition-9/food-safety-code--food-manufacturing--edition-9), 11.1.6, and [21 CFR 117](https://www.ecfr.gov/current/title-21/chapter-I/subchapter-B/part-117), 117.20(b)(4). A recurring job holds the filter, coil and pressure readings as found and as left.

### What are the OSHA regulations for ammonia?

[OSHA's process safety rule](https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.119) can cover an ammonia system, depending on how much ammonia it holds (Appendix A lists the quantity). It asks for each inspection and test to be documented (paragraph (j)(4)(iv)). A job per unit holds each of those and the files. Your process safety program stays yours, and the software does not make a plant compliant.

### How often should a chiller be serviced?

The maker's manual and your plant's own procedure set the interval for a chiller or a compressor. Set it once and the next visit lands on that calendar date as a [recurring job](https://hvacsoftware.com/preventive-maintenance/recurring-visits/), with the readings entered by a technician.

### Does it monitor cold room temperatures or raise a work order when a room drifts?

No, a person enters the readings and your temperature monitoring system stays in place. When a room does drift, the job records the repair with the readings as found and as left.

### How does maintenance stay out of the sanitation window, and how is the release recorded?

Recurring jobs sit on calendar dates you set around sanitation, and the release is recorded as a clearance on the job. Nothing blocks a job or a line: the clearance is a record, not a lock.

### What does it not do for a food plant?

HVACSoftware has no CIP or allergen workflow, no e-signatures and no claim to 21 CFR Part 11, and recurring work does not start from run hours, batches or sensors. Those records stay in your own systems, and the software holds the maintenance record only.

### Does it fit a brewery, a dairy or a bakery?

Yes, the plant type is a field on the record, so a brewery, a dairy, a bakery or a frozen plant each fit.

Still have a question? [Book an intro meeting](https://calendly.com/jeel-fieldcamp/30min?utm_source=hvacsoftware.com&utm_medium=markdown&utm_content=manufacturing-food-and-beverage)

## Start with one cold room

30 minutes about your plant and the record your auditor asks for.

[Book an intro meeting](https://calendly.com/jeel-fieldcamp/30min?utm_source=hvacsoftware.com&utm_medium=markdown&utm_content=manufacturing-food-and-beverage)

---

Also here: [llms.txt](https://hvacsoftware.com/llms.txt)